This website uses Cookies in order to offer a better experience for the user. For more details click here!
I understand and I accept cookies
I understand and I don't accept cookies
+36-23/560-023   -   Stores Network
  • EN
+36-23/560-023   -   Stores Network
  • Home
  • Motors
    • Industrial and agriculture
      Industrial and agriculture
    • Generators Engine
      Generators Engine
    • Naval Engines
      Naval Engines
    • Gas Engines
      Gas Engines
  • Generators
    • FGWilson Generators
      FGWilson Generators
    • Control panels
      Control panels
  • Agricultural tractors
    • IRUM TAGRO 102 (Stage V)
      IRUM TAGRO 102 (Stage V)
    • IRUM TAG 24R
      IRUM TAG 24R
    • IRUM TAG 24RH
      IRUM TAG 24RH
    • IRUM TAG 50C
      IRUM TAG 50C
    • IRUM TAG 50CH
      IRUM TAG 50CH
    • IRUM TAG 60C
      IRUM TAG 60C
    • IRUM TAG 60CH
      IRUM TAG 60CH
  • Forestry Tractors – Skidders
    • SKIDDER 690 S5
      SKIDDER 690 S5
    • Skidder 690 PE
      Skidder 690 PE
    • Skidder 2012
      Skidder 2012
    • Skidder 2012 PowerShift
      Skidder 2012 PowerShift
    • Skidder 2012 G
      Skidder 2012 G
  • Spare Parts
  • Service
  • About Us
    • About Company
    • Careers
    • Our Network
    • Contact Us

ATI Load transfer control panels (over 2000 Amps)

Contacteaza-ne »
  • Kezdőlap
  • Generators
  • Control panels
  • ATI Load transfer control panels (over 2000 Amps)
  • Presentation
  • Main features
  • Compare Control Panels

Presentation

The FG Wilson ATI Load Transfer Panel range offers an electronically controlled response to power outages. With flexible, upgradeable options and a high level of functionality FG Wilson transfer panels provide 24-hour automatic control of standby generator sets, 365 days a year.

Benefits

  • Fully automatic mains failure sensing and generator set start signal
  • Pre-programmed enabling the panel to run on installation with the ability to customise if necessary
  • Fast acting switches reduce transfer times between set and utility power
  • Available from 2000 – 3200A
  • Seamless integration with FG Wilson digital control panels

Features

  • Automatic and manual operation
  • Automatically provides generator set start signal upon detection of mains failure, overvoltage or loss of phase
  • Automatic mains re-transfer function
  • Flexible, upgradeable options
  • Test operations and sequences accessible from panel or remotely
  • Manual switch operation possible via external handle
  • LED functions display showing generator set / mains availability and switch position
  • LCD display for voltage and timers
  • Load transfer panel range meets ATS IEC 60947-6-1 standard

Main features

System Status Indication

Shows status of utility power, generator set and switch at all times.

RS485 Communications Module

Enables access to the system remotely through telephone or PC via modem.

Volt Free Contacts

For power available and generator available

Auto/Manual/Test Mode Status Indication

Allows on/off load tests at routine service checks.

LCD Display

Shows detailed status of system at all times for greater awareness and control.

Power Metering

To measure load current, kW, kVAr, kVA, power factor.

Keypad

For straightforward programming and testing. Password protection is included.

Programmable Countdown Timers

Set routine times for delay on starts, delay on transfer, delay on re-transfer and run on timer.

Lightning Protection

Ensures the safety of system during lightning storms (includes volt free contacts for utility power and generator set).

Auxiliary Contacts

Auxiliary / volt free contacts for remotely monitoring system; switch position, padlock and automatic or manual operation

Bottom Gland Plate

Removable gland plate providing increased accessibility with a sizeable area for utility power and generator set cables to be connected.

Wall Mounting Kit

Panel can be wall mounted for greater flexibility in positioning (ATI 250 and 400).

Solid Neutral

Allows the connection of neutral cables from utility power, generator set and load without having the neutral broken by the switch during transfer operations.

Note:
– Standard features are marked with circle and optional features are marked with square .
Compare control panels
FEATURES AND OPTIONS CTI ATI < 1600A ATI > 2000A
Motorised Mechanically Held Switch
Facility for manual changeover Yes Yes Yes
Protection
Utlity power available Yes Yes Yes
Utility power on load Yes Yes Yes
Generator available / Generator on load Yes Yes Yes
Utility power and generator off load Yes Yes Yes
Manual mode / Automatic mode Yes Yes Yes
Test on load / Test off load Yes Yes Yes
Manual re-transfer for enabled / required Yes Yes Yes
Power / Error indication (LED) Yes Yes Yes
Facia
Universal symbols to allow
for multiple languages
Yes Yes Yes
Liquid Crystal Display
Utility Power L1-2, L1-3, L2-3 voltage Yes Yes Yes
Utility Power L1-N, L2-N, L3-N voltage Yes Yes Yes
Generator Set L1-N, L2-N, L3-N voltage Yes Yes Yes
Generator Set L1-2, L1-3, L2-3 voltage Yes Yes Yes
Utility Power Frequency /
Generator Set Frequency
Yes Yes Yes
Number of times switch transfers
from mains to generator set
Yes Yes Yes
Timer settings Yes Yes Yes
Standards
Complete enclosure meets
standard IEC 60947-6-1
Yes Yes Yes
Swith meets standard AC31B Yes Yes Yes
Controls
Under / Over frequency failure Yes Yes Yes
Under / Over frequency restoration Yes Yes Yes
Manual / Auto re-transfer Yes Yes Yes
Mode select push button Yes Yes Yes
Under / Over Volts Failure Yes Yes Yes
Under / Over Volts Restoration Yes Yes Yes
Delay on Start Timer Yes Yes Yes
Delay on Transfer Yes Yes Yes
Delay on Re-Transfer Yes Yes Yes
Dead Band Timer Yes Yes Yes
Run On Timer Yes Yes Yes
Auto / Manual Control Keyswitch Yes Yes Yes
Lamp Test Pushbutton Yes Yes Yes
Padlock facility Yes Yes Yes
Selection between
Contactor or Switch Mode
Yes No No
Cable entry
Top Yes No No
Bottom Yes Yes Yes
Load Terminal Extensions
Improving ease of installation Optional No No
Auxiliary Contacts
For monitoring of switch position
(Including padlocking & auto / manual)
No Yes Yes
Lightning Protection
Ensuring the safety of system
during lightning storms
Optional Optional Optional
Ingress Protection IP54
Protection for control module Optional Optional Yes
Power Metering
To measure load current, kW, kVAr,
kVA, Power factor
No Yes No
Volt Free Cotacts
For utility power availability &
generator available
Yes Optional Optional
Communication Module
Plug in module that uses Jbus/modbus protocol to allow remote
communication of the change
over system No Optional Optional
Voltage Sensing Tap
Allowing for pole voltage sensing Optional No No
Solid Neutral Kit
To connect neutral cables from the mains,
generator set and load
Optional Optional No
Terminal Shroud
For added protection Optional No No