This website uses Cookies in order to offer a better experience for the user. For more details click here!
I understand and I accept cookies
I understand and I don't accept cookies
+36-23/560-023   -   Stores Network
  • EN
+36-23/560-023   -   Stores Network
  • Home
  • Webshop
  • Motors
    • Industrial and agriculture
      Industrial and agriculture
    • Generators Engine
      Generators Engine
    • Naval Engines
      Naval Engines
    • Gas Engines
      Gas Engines
  • Generators
    • FGWilson Generators
      FGWilson Generators
    • Control panels
      Control panels
  • Agricultural tractors
    • IRUM TAGRO 102 (Stage V)
      IRUM TAGRO 102 (Stage V)
    • IRUM TAG 24R
      IRUM TAG 24R
    • IRUM TAG 24RH
      IRUM TAG 24RH
    • IRUM TAG 50C
      IRUM TAG 50C
    • IRUM TAG 50CH
      IRUM TAG 50CH
    • IRUM TAG 60C
      IRUM TAG 60C
    • IRUM TAG 60CH
      IRUM TAG 60CH
  • Forestry Tractors – Skidders
    • SKIDDER 690 S5
      SKIDDER 690 S5
    • Skidder 690 PE
      Skidder 690 PE
    • Skidder 2012
      Skidder 2012
    • Skidder 2012 PowerShift
      Skidder 2012 PowerShift
    • Skidder 2012 G
      Skidder 2012 G
  • Spare Parts
  • Service
  • About Us
    • About Company
    • Careers
    • Our Network
    • Contact Us

1002T analog control panel

Contacteaza-ne »
  • Kezdőlap
  • Generators
  • Control panels
  • 1002T analog control panel
  • Presentation
  • Compare Control Panels

Presentation

The 1002T Control Panel is equipped with all the necessary generator set instrumentation and protection devices, whilst providing the straightforward functionality and reliability of a key-start panel.

Benefits

  • Simplified monitoring of generator set conditions at a glance
  • Heavy duty, reliable industrial push buttons and switches
  • Visual individual warning and shutdowns through LED’s
  • Universal pictorial fault lamp indicators

Features

  • Analogue metering: voltmeter, ammeter, hours-run
  • counter, combined frequency and tachometer
  • 7 position voltmeter phase selector switch
  • 4 position ammeter phase selector switch
  • Preheat (start aid active LED indicator)
  • DC supply from starting battery protected by MCB’s
  • Printed circuit board assemblies
  • Multi-pin plug and socket connections for ease of servicing
  • Engine protection through critical shutdowns
  • AC instruments are 90° deflection, flush mounted
  • AC instruments in accordance with IEC60051 and
  • 60529, DIN43700 and 43718, BSEN60051 and 61010, UL94


Features and Options 1002T DCP-10 DCP-20 PW 1.1 PW 1.1+ PW 2.1 EG 2500 EG 3200+
Instrumentation
LCD Display with Auto Power ff No No No Yes Yes Yes Yes Yes
Battery Trickle Charge Ammeter No No No Optional Optional Optional Optional Optional
Audible Alarm No Yes Yes Optional Optional Optional Optional Optional
Remote Annunciator No No No No Optional Optional Optional Optional
AC Metering
Voltmeter 3-phase
( L – L & L – N )
Yes Yes Yes Yes Yes Yes Yes Yes
Amps
(per phase and average)
Yes Yes Yes Yes Yes Yes Yes Yes
Frequency Yes Yes Yes Yes Yes Yes Yes Yes
kW
(total & per phase)
No No Yes No No Yes Yes Yes
kVA
(total & per phase)
No No Yes No No Yes Yes Yes
kVAr
(total & per phase)
No No Yes No No Yes Yes Yes
Power Factor
(overall and per phase)
No No Yes No No Yes Yes Yes
kW Hours No No Yes No No Yes Yes Yes
kVAr Hours No No Yes No No Yes Yes Yes
DC Metering
Battery Voltmeter No Yes Yes Yes Yes Yes Yes Yes
Engine Hours Run Yes Yes Yes Yes Yes Yes Yes Yes
Engine Jacket Water Temperature
(in °C or °F)
No Yes Yes Yes Yes Yes Yes Yes
Lube Oil Pressure
(in Psi, kPA or bar)
No Yes Yes Yes Yes Yes Yes Yes
Engine Speed
(rpm)
No No Yes Yes Yes Yes Yes Yes
Crank Attempt Counter No No No No Yes Yes Yes Yes
Start Counter No No No No Yes Yes Yes Yes


Protection 1002T DCP-10 DCP-20 PW 1.1 PW 1.1+ PW 2.1 EG 2500 EG 3200+
Fail to Start No Yes Yes Yes Yes Yes Yes Yes
Low Oil Pressure Yes Yes Yes Yes Yes Yes Yes Yes
High Engine Temperature Yes Yes Yes Yes Yes Yes Yes Yes
Underspeed, Overspeed No Yes Yes Yes Yes Yes Yes Yes
Loss of Engine Speed Detection No No No Yes Yes Yes Yes Yes
Low / High Battery Voltage No Yes Yes Yes Yes Yes Yes Yes
Battery Charger Failure
(if Battery Charger fitted)
No No No Yes Yes Yes Yes Yes
Under Volts, Over Volts No Yes Yes Yes No Yes Yes Yes
Under Frequency, Over Frequency No No No Yes No Yes Yes Yes
Overcurrent No No No No Yes Yes Yes Yes
Configurable Sender Input
(for ‘Oil Temperature’ or ‘Fuel Level’ options only)
No No No Yes No Yes Yes Yes
Earth Leakage Protection No No No Optional Optional Optional Optional Optional
Earth Fault Protection No No No Optional Optional Optional Optional Optional
Low Fuel Level Alarm No Optional Optional Optional Optional Optional Optional Optional
Low Fuel Level Shutdown No No No Optional Optional Optional Optional Optional
High Fuel Level Alarm No No No Optional Optional Optional Optional Optional
Fuel Transfer System Control No Optional Optional No Optional Optional Optional Optional
Low Coolant Level Shutdown No No No Optional Optional Optional Optional Optional
Low Coolant Temperature Alarm No Yes Yes Yes Yes Yes Optional Optional
High Lube Oil Temperature Shutdown No No No Optional Optional Optional Optional Optional
Overload via Alarm Switch on Breaker No No No Optional Optional Optional No Optional
Overload via Over Current Relay No No No Optional Optional No No Optional
Low Gas Pressure No No No No No No No Optional
High Gas Pressure No No No No No No No Optional
High Exhaust Temperature Alarm No No No Yes Yes Yes Optional Optional
Protection Monitoring
Name of Each Event No No No Yes Yes Yes Yes Yes
Engine Hours at First Occurrence of Event No No No Yes Yes Yes Yes Yes
Time and Date of First Occurrence of Event No No No No No Yes Yes Yes
Engine Hours at Last Occurrence of Event No No No Yes Yes Yes Yes Yes
Number of Occurrences of Event No No No Yes Yes Yes Yes Yes
Spare Fault Channels
Number of Channels Available 0 0 4 3 5 5 5 6
Exceptions
On models P730P1 – P1100E1 No No No No 3 3 4 5
On models P1250 – P2500-1 No No No No 2 2 3 4


Controls 1002T DCP-10 DCP-20 PW 1.1 PW 1.1+ PW 2.1 EG 2500 EG 3200+
2 LED Status Indicators
(1 red shutdown, 1 amber warning)
No No Yes Yes Yes Yes Yes Yes
Run key, Auto Key and Stop Key with LED indicators No Yes Yes Yes Yes Yes Yes Yes
Lamp Test Yes Yes Yes Yes Yes Yes Yes Yes
Alarm Acknowledge Key No Yes Yes Yes Yes Yes Yes Yes
Menu Navigation Keys No Yes Yes Yes Yes Yes Yes Yes
Dedicated Key to reset all events No No No Yes Yes Yes No No
Engine and AC Metering Short Cut Keys No No No Yes Yes Yes No No
Main Menu and Event Log Short Cut Keys No No No Yes Yes Yes Yes Yes
Control Module Keys with Tactile Feedback No No No Yes Yes Yes Yes Yes
CAN 1 Data Link – J1939 for communicating with electronic engine control modules No No No Yes Yes Yes Yes Yes
CAN 2 Accessory Data Link – for additional modules remote annunciator, digital input/output module No No No No No Yes Yes Yes
Remote Monitoring and Control Data Link (ModBus) No No No No No Yes Yes Yes
Real Time Clock No No No No Yes Yes Yes Yes
Service Maintenance Interval Warning No No No No No Yes Yes Yes
Remote Monitoring and Control No No No No No Optional Optional Optional
Static Battery Charger No No No Optional Optional Optional Yes Yes
Static Battery Charger with Auto Boost No Optional Optional Optional Optional Optional Optional Optional
Volt Free contacts for: Common Alarm & Generator Set Running No Optional Optional Optional Optional Optional Optional Optional
Engine Coolant Heater Controls No No No Optional Optional Optional Optional Optional
Control Panel Heater No No No No Optional Optional No Optional
Volts Adjust Potentiometer No No No Optional Optional Optional Yes Yes
Speed Adjust Potentiometer No No No Optional Optional Optional Yes Yes
Speed Adjust Switch No No No Optional Optional Optional Optional Optional
Oil Temperature Display No No No No Optional Optional Optional Optional
Oil Temperature Gauge No No No Optional Optional Optional No No
Lube Oil Temeperature displayed on LCD screen No No No Optional Optional Optional Optional Optional
Fuel Level Switch No Optional No Optional No No Optional Optional
Fuel Level Sender & Display No No Optional No Optional Optional Optional Optional
Panel Lockdown Stop Push Button with security key No No No Optional Optional Optional No No
Netbiter Internet Monitoring and Control Unit No No No No No No Optional Optional
Mains Load Sensing Unit No No No No No No No Optional
Additional 8 inputs and 8 outputs No No No No No No No Optional


Contact Us »

© Copyright 2025 All Rights Reserved MÁVIPROD Magyarország Kft.